Reset the Program (Engineer) Code
  1. Remove power from the keypad
  2. Depress and hold the Star button
  3. Whilst the star button is depressed reconnect the power
  4. You will hear a tone which lasts for approx. 2 seconds.
  5. Let go of the star button
  6. Enter 4 digits (0 - 9) into the keypad
      • This is the new Program (Engineer) code.
    • Does this new code work?
      • Yes - continue
      • No
        • Disconnect everything from the keypad terminals except for power and repeat the above
        • Were you able to reset the Program (Engineer) code?
          • Yes
            • It is likely that the keypad circuit board is being upset by an external source.
            • Make sure that the connections are correct and in particular check that the lock release has a Tranzil fitted.
            • If connected to gate automation system, insert a relay bewteen the keypad and the gate automation control to prevent further spikes damaging the keypad electronics
          • No -
            • keypad is faulty - replace keypad