SRS DC30 Keypad
Reset the Program (Engineer) Code
|
|
- Remove power from the keypad
- Depress and hold the Star button
- Whilst the star button is depressed reconnect the power
- You will hear a tone which lasts for approx. 2 seconds.
- Let go of the star button
- Enter 4 digits (0 - 9) into the keypad
- This is the new Program (Engineer) code.
- Does this new code work?
- Yes - continue
- No
- Disconnect everything from the keypad terminals except for power and repeat the above
- Were you able to reset the Program (Engineer) code?
- Yes
- It is likely that the keypad circuit board is being upset by an external source.
- Make sure that the connections are correct and in particular check that the lock release has a Tranzil fitted.
- If connected to gate automation system, insert a relay bewteen the keypad and the gate automation control to prevent further spikes damaging the keypad electronics
- No -
- keypad is faulty - replace keypad
|